ChromoTek iST HA-Trap IP-MS Sample Preparation Kit

Kit for IP/Co-IP of HA-fusion proteins and sample preparations for mass spectrometry (MS)

Specificity

HA-Tag (sequence YPYDVPDYA)

Applications

IP, Co-IP, MS

Type

Nanobody

Conjugate

Agarose

Cat no : atak-iST

Synonyms

Hemagglutinin tag, HA, HA-tag, HA-tag Trap Agarose



Product Information

Kit for IP/Co-IP of HA-fusion proteins and sample preparations for mass spectrometry (MS)

DescriptionThe iST HA-Trap Kit enables researchers to process HA-fusion proteins and their interacting partners for mass spectrometry analysis by including the ChromoTek HA-Trap for IP /Co-IP of HA-fusion proteins and the PreOmics iST buffers and cartridges required for bottom-up proteomic sample preparation. This robust method yields purified peptides while dramatically reducing contamination and sample loss. Each kit accomodates up to eight samples and includes pull-down material for 2 controls.
ApplicationsIP, Co-IP, MS
Specificity/TargetBinds specifically to the HA-tag (sequence YPYDVPDYA) fused to a protein of interest at N-, C- or internal position. Please note that the affinity is highest for a C-terminal fusion. There is no cross-reactivity to other common peptide tags such as the His6-tag, FLAG-tag, Spot-Tag, V5-tag, Strep-tag, or C-tag (other tags not tested). Background binding to host cell proteins from a range of organisms such as human, mouse and dog cell lines or yeast and plants is low.
Binding Capacity20 ug of recombinant HA-tagged protein (~30 kDa) per 25 uL bead slurry
ConjugateAgarose beads; ~90 um (cross-linked 4% agarose beads)
Elution buffer2x SDS-sample buffer (Lammli)
TypeNanobody
ClassRecombinant
HostAlpaca
Affinity (KD)6 nM for C-terminal HA-tags and ca. 180 nM for N-terminal fusions.
Compatibility with mass spectrometryThe HA-Trap is optimized for on-bead digestion.
Storage Buffer20% ethanol
Storage ConditionShipped at ambient temperature. Upon receipt store HA-Trap at +4°C and Digest at -20°C.

Kit components

Component Description
HA-Trap Agarose8 reactions plus 2 controls
DigestEnzyme Trypsin-mix to digest proteins
Resuspend bufferProtease reconstitution buffer for enzymes
Lyse bufferDenature, reduce, and alkylate proteins
Stop solutionStop the enzymatic activity
Wash 1 bufferClean up peptides from hydrophobic contaminants
Wash 2 bufferClean up peptides from hydrophillic contaminants
Elution bufferElute peptides from the cartridge
LC-LoadLoad peptides on reversed-phase LC-MS column
CartridgesCartridge for 1 to 100 ug protein starting material
Waste TubesTube for collecting waste after washing steps
Collection TubesTube for collecting peptides after elution
AdaptersEnables placing a cartridge into a tube
CapsCap to optionally close the cartridge's bottom